Author Maxime Bès de Berc, Dimitri Zigone, Peter Danecek, Alain Steyer, Francesco Zanolin, Alessia Maggi, Jean‐Yves Thoré, Armelle Bernard, Hervé Blumentritt, Sophie Lambotte, Jean‐Jacques Lévêque, Luis Rivera, Olivier Alemany, Philippe Possenti, Martin Vallée, Eléonore Stutzmann, Adriano Cavaliere, Nathalie Cotte, Stefano Marino, Baptiste Gombert, Wenceslas Marie‐Sainte, Nicolas Leroy, Constanza Pardo, Frédérick Pesqueira, Céleste Broucke doi  openurl
  Title A New Posthole Seismometer at Concordia Permanent Research Facility in the Heart of the Icy East Antarctic Plateau Type Journal
  Year (down) 2023 Publication Seismological research letters Abbreviated Journal  
  Volume Issue Pages  
  Keywords  
  Abstract In the Southern Hemisphere, the prevalence of oceans and the difficulty of access to land result in reduced coverage of seismological stations, limiting our detailed knowledge of Earth’s structures and of large earthquakes sources. This situation is exacerbated inside the antarctic continent, where only two permanent seismic stations are currently available (IU.QSPA at South Pole and G.CCD). The CCD station, built in early 2000s with state‐of‐the‐art surface instrumentation and located at the French–Italian Concordia base (75° S, 123° E), has been providing seismological data since 2008. However, it suffers from several problems: the vault is deformed by the hydrostatic pressure of the snow, the firn waveguide traps anthropogenic noise from the base causing strong noise below 1 s, and a coupling defect limits the performance above 30 s on the horizontal channels. To ensure the continuity of CCD and to improve its overall performance, we started in 2014 to plan the installation of a borehole seismometer at the site. In this article, we describe in detail this renovation of CCD and some examples of data analysis. The new borehole sensor shows that short‐period disturbances are largely attenuated (−20 dB at 0.1 s) compared to the surface installation and that the horizontal channels have a lower noise level at long periods (−8 dB at 100 s). Data for all components are below the standard noise model between 0.1 and 0.2 s, which makes this sensor one of the quietest installations in the world for this bandwidth. For periods >600 s we observe atmospheric pressure‐related perturbations on the vertical component. Despite this problem, the new CCD borehole station is a success with better‐than‐expected performances at all periods <600 s. The data produced are now distributed in the world’s data centers as G.CCD.20 and we encourage the scientific community to use the data for all studies requiring seismograms from Antarctica.  
  Programme 133  
  Campaign  
  Address  
  Corporate Author Thesis  
  Publisher Place of Publication Editor  
  Language Summary Language Original Title  
  Series Editor Series Title Abbreviated Series Title  
  Series Volume Series Issue Edition  
  ISSN 0895-0695 ISBN Medium  
  Area Expedition Conference  
  Notes Approved yes  
  Call Number Serial 8663  
Permanent link to this record
Select All    Deselect All
 |   | 
Details
   print